[FUG-BR] Como interpretar smartmontools
Zhu Sha Zang
zhushazang em yahoo.com.br
Quarta Abril 8 18:58:36 BRT 2015
On 04/08/2015 03:32 PM, Vitor Hugo wrote:
> This email was generated by the smartd daemon running on:
>
> host name: nas4free.local
> DNS domain: local
> NIS domain: [None]
>
> The following warning/error was logged by the smartd daemon:
>
> TEST EMAIL from smartd for device: /dev/ada0
>
> Device info:
> SAMSUNG HD322HJ, S/N:S1RLJ50SB84327, WWN:5-0024e9-40015e921, FW:1AC01118, 320 GB
>
> For details see host's SYSLOG. smartctl 6.0 2012-10-10 r3643 [FreeBSD 9.1-RC3 amd64] (local build)
> Copyright (C) 2002-12, Bruce Allen, Christian Franke, www.smartmontools.org
>
> === START OF INFORMATION SECTION ===
> Model Family: SAMSUNG SpinPoint F1 DT
> Device Model: SAMSUNG HD322HJ
> Serial Number: S1RLJ50SB84327
> LU WWN Device Id: 5 0024e9 40015e921
> Firmware Version: 1AC01118
> User Capacity: 320,072,933,376 bytes [320 GB]
> Sector Size: 512 bytes logical/physical
> Device is: In smartctl database [for details use: -P show]
> ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b
> Local Time is: Tue Apr 7 19:31:23 2015 BRT
> SMART support is: Available - device has SMART capability.
> SMART support is: Enabled
>
> === START OF READ SMART DATA SECTION ===
> SMART overall-health self-assessment test result: PASSED
>
> General SMART Values:
> Offline data collection status: (0x00) Offline data collection activity
> was never started.
> Auto Offline Data Collection: Disabled.
> Self-test execution status: ( 0) The previous self-test routine completed
> without error or no self-test has ever
> been run.
> Total time to complete Offline
> data collection: ( 4072) seconds.
> Offline data collection
> capabilities: (0x7b) SMART execute Offline immediate.
> Auto Offline data collection on/off support.
> Suspend Offline collection upon new
> command.
> Offline surface scan supported.
> Self-test supported.
> Conveyance Self-test supported.
> Selective Self-test supported.
> SMART capabilities: (0x0003) Saves SMART data before entering
> power-saving mode.
> Supports SMART auto save timer.
> Error logging capability: (0x01) Error logging supported.
> General Purpose Logging supported.
> Short self-test routine
> recommended polling time: ( 2) minutes.
> Extended self-test routine
> recommended polling time: ( 69) minutes.
> Conveyance self-test routine
> recommended polling time: ( 8) minutes.
> SCT capabilities: (0x003f) SCT Status supported.
> SCT Error Recovery Control supported.
> SCT Feature Control supported.
> SCT Data Table supported.
>
> SMART Attributes Data Structure revision number: 16
> Vendor Specific SMART Attributes with Thresholds:
> ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
> 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
> 3 Spin_Up_Time 0x0007 091 091 011 Pre-fail Always - 3550
> 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 921
> 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
> 7 Seek_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
> 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 0
> 9 Power_On_Hours 0x0032 094 094 000 Old_age Always - 31493
> 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0
> 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0
> 12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 853
> 13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0
> 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
> 184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always - 0
> 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
> 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
> 190 Airflow_Temperature_Cel 0x0022 083 059 000 Old_age Always - 17 (Min/Max 17/17)
> 194 Temperature_Celsius 0x0022 081 054 000 Old_age Always - 19 (Min/Max 17/19)
> 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 128
> 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
> 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
> 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
> 199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 0
> 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0
> 201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0
>
> SMART Error Log Version: 1
> No Errors Logged
>
> SMART Self-test log structure revision number 1
> No self-tests have been logged. [To run self-tests, use: smartctl -t]
>
>
> SMART Selective self-test log data structure revision number 1
> SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
> 1 0 0 Not_testing
> 2 0 0 Not_testing
> 3 0 0 Not_testing
> 4 0 0 Not_testing
> 5 0 0 Not_testing
> Selective self-test flags (0x0):
> After scanning selected spans, do NOT read-scan remainder of disk.
> If Selective self-test is pending on power-up, resume after 0 minute delay.
> -------------------------
> Histórico: http://www.fug.com.br/historico/html/freebsd/
> Sair da lista: https://www.fug.com.br/mailman/listinfo/freebsd
Assim, na lata? Sem um jantar, conversinha amigável antes...
Apresentações???
Anyway, RTFM Dude!
Mais detalhes sobre a lista de discussão freebsd